    ESCAPE 1200

     

    Recommended heating area                                     250 – 1,200 ft²
    Size                                                              18 1/2″ W X 28 7/8″ D X 30 1/8″ H
    Maximum log length                                                          17″
    Average particulate emission rate                                   1.8 g/h

    Most compact unit in the series, the Escape 1200 is the perfect choice for heating homes up to 1,200 ft². With only 1.8 g/h of particulate emissions, this EPA certified wood stove puts out an impressive 45,000 BTU/h. The bottom of its combustion chamber is deeper than other models in its category and allows a greater accumulation of ashes, and thus able to empty them less frequently. A simple model; reliable and robust.

    **Included:**pedestal, air deflector, ceramic glass, cast iron door with adjustable hinges, ash lip, air damper, stainless steel heat shield

    ▪ Up to 5 hours burn time
    ▪ Up to 17″ logs
    ▪ 1.55 ft³ firebox
    ▪ EPA certified
    ▪ Proudly made in Canada
    ▪ Limited lifetime warranty
    ▪ Certified for mobile home and alcove installation

    Any installation must be done according to the data and drawings detailed in the owner’s manual.

    Fuel type Dry cordwood (16″ recommended)
    Recommended heating area(9) 250 – 1,200 ft²
    Overall firebox volume 1.8 ft³
    EPA loading volume 1.55 ft³
    Maximum burn time(9) 5 h
    Maximum heat output-dry cordwood(4) 45,000 BTU/h (13.19 kW)
    Minimum overall heat output rate(4) (5) 12,124 BTU/h (3.55 kW)
    Maximum overall heat output rate(4) (5) 26,700 BTU/h (7.83 kW)
    Average overall efficiency-dry cordwood (HHV)(5) (6) 74 %
    Average overall efficiency-dry cordwood (LHV)(5) (7) 79 %
    Optimum efficiency(1) (2) 80 %
    Optimum heat transfer efficiency(8) 79 %
    Average particulate emission rate(3) 1.8 g/h
    Average CO(10) 74 g/h
    Size Small
    Alcove installation approved Yes
    Mobile home approved Yes, with fresh air intake
    Certified according to applicable standards By an accredited laboratory (CAN/USA)
    Overall dimension (Width) 18 1/2″
    Overall dimension (Height) 30 1/8″
    Overall dimension (Depth) 28 7/8″
    Premium quality blower included (CFM) Optional
    Combustion technology Non-catalytic
    Stainless-steel secondary-air system Yes
    Flue outlet diameter 6″
    Distance-center of the flue outlet to back unit 6 5/8″
    Distance-center of the flue outlet to side unit 9 1/4″
    Recommended chimney diameter 6″
    Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
    Minimum chimney height 12′
    Door type Single, glass with cast iron frame
    Door opening size (Width) 12″
    Door opening size (Height) 7 5/8″
    Glass type Ceramic glass
    Steel thickness-body 3/16″
    Steel thickness-top 1/4″
    Firebox size (Width) 14 1/4″
    Firebox size (Height) 11 3/4″
    Firebox size (Depth) 19 1/8″
    Log positioning Loading over depth
    Maximum log length 17″
    Firebox lined with refractory bricks Yes
    Baffle type High quality vermiculite
    High-efficiency certified appliance Yes, EPA 2020 approved
    Canadian Standard (emissions) CSA B415.1-10
    USA Standard (emissions) EPA
    Canadian Standard (safety) ULC S627
    USA Standard (safety) UL 1482, UL 737
    Warranty Limited lifetime
    Shipping weight 262 lb (119 kg)
    lzM6UlOkR5aslul-pwso2A
    Clearances to combustibles*
    Canada                                                                                United-States
    Single wall pipe      Double wall pipe        Single wall pipe              Double wall pipe
    Clearance – Side wall 18″                                       18″                                  18″                                         18″
    Clearance – Corner 11″                                          7″                                  11″                                          7″
    Clearance – Back wall 14″                                         6″                                  12″                                          6″
    Clearance – Base of the unit to ceiling** 84″                                       84″                                 84″                                        84″

     

     

     

    *The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner’s manual, catalogues, flyers, magazines and/or web sites).

    **Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

    • 1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
    • 2. Optimum overall efficiency at a specific burn rate (LHV).
    • 3. This appliance is officially tested and certified by an independent agency.
    • 4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
    • 5. As measured per CSA B415.1-10 stack loss method.
    • 6. Higher Heating Value of the fuel.
    • 7. Lower Heating Value of the fuel.
    • 8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
    • 9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
    • 10. Carbon monoxyde.